AMETEK Programmable Power MX / RS Series SCPI Programming Manual
164 MX / RS Series
Bit Signal Meaning
Operation Status Group
0 CAL Interface complete its calibration cycle
3 TRANS Transient is completed
4 MEAS Measurement is completed
Questionable and Questionable Instrument Isummary Status Groups
0 OV Output voltage faulted, output voltage differ from program
value
1 OCP The overcurrent protection circuit has tripped
3 TO An overtemperature condition has occurred
9 RI The remote shut down state is active
12 Clrms The rms current limit circuit is active
14 n/a
Standard Event Status Group
0 OPC Operation complete
2 QYE Query error
3 DDE Device-dependend error
4 EXE Execution error
5 CME Command error
7 PON Power-on
Status Byte and Service Request Enable Registers
3 QUES Questionable status summary bit
4 MAV Message Available summary bit
5 ESB Event Status Summary bit
6 MSS Master Status Summary bit
RQS Request Service bit
7 OPER Operation status summary bit
Table 7-2: Configuration of Status Register